Allied Telesis AT-WDRPS-80 Leaflet

Page of 2
Wiring the AT-WDRPS-80 Power Supply
Warning
As a safety precaution, a 10 Amp circuit breaker should be installed at the 
supply end of the cable to be used with this LAN equipment.  
ALWAYS connect the wiring to the LAN equipment first before connecting 
the wiring to the breaker. To avoid the danger of physical injury from 
electrical shock, do not work with HOT feeds. Always be sure that the 
breaker is in the OFF position before connecting the wiring to the breaker.
Note
A tray cable is required to connect the power source if the unit is powered by 
centralized DC power. The tray cable must be UL listed Type TC tray cable and 
rated at 600 V and 90 degree C, with three conductors, minimum 14 AWG.
1.
On the rear side of the chassis is a DC terminal block labeled POWER SUPPLY B. 
Starting from the left side of the terminal block, identify the positive, frame 
ground, and negative terminals using either the diagram adjacent to the 
terminal block or the illustration here:
2.
With a 14-gauge wire-stripping tool, strip the three wires in the tray cable 
coming from the DC input power source to 8 mm 
±
 1 mm (0.31 in 
±
 0.039 in).
Warning
Do not strip more than the recommended amount of wire. Stripping more 
than the recommended amount can create a safety hazard by leaving 
exposed wire on the terminal block after installation.
8 mm ± 1 mm
(0.31in ± 0.039 in)
3.
Connect the frame ground wire to the terminal marked with the ground 
symbol by inserting the wire into the terminal and tightening the connection 
with a flathead screwdriver. 
Warning
When installing this equipment, always ensure that the frame ground 
connection is installed first and disconnected last.
4.
Connect the positive feed wire to the terminal block marked (+).
5.
Connect the negative feed wire to the terminal block marked (-).
Warning
"Safety Hazard"- Check to see if there are any exposed copper strands 
coming from the installed wires. When this installation is done correctly 
there should be no exposed copper wire strands extending from the 
terminal block. Any exposed wiring can conduct harmful levels of electricity 
to persons touching the wires.
6.
Secure the tray supply cable near the rack framework using multiple cable ties 
to minimize the chance of the connections being disturbed by casual contact 
with the wiring. Use at least four cable ties separated four inches apart with 
the first one located within six inches of the terminal block.
Note
This system will work with a positive grounded or negative grounded DC 
system.
Technical Specifications
Electrical Rating
Input Voltage
36-60 V DC, 7.9A maximum
Power Comsumption
75 watts maximum
Environment
Operating Temperature:
0° C to 40° C (32° F to 104° F)
Storage Temperature:
-25° C to 70° C (-13° F to 158° F) 
Operating Relative Humidity:
5% to 90% RH (non-condensing)
Storage Relative Humidity:
5% to 95% RH (non-condensing)
Operating Altitude Range:
Up to 3,000 m (9,843 ft)
Electrical Safety and Emission Statement
Standards: This product meets the following standards when installed in compliant host equipment.
Emission
FCC Class A, EN55022 Class A, VCCI Class A
WARNING
In a domestic environment this product may cause radio interference in which case the user may be 
required to take adequate measures. 
Immunity
EN50082-1
Electrical Safety UL60950 (cULus), EN60950 (TUV)
Copyright 
 2003 Allied Telesyn, Inc. All rights reserved. 
No part of this publication may be reproduced without prior written permission from Allied Telesyn Inc.
U.S. Federal Communications Commission 
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to 
Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when 
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful 
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful 
interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to 
operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du 
Canada.
4
5
6