Avaya 106760804 User Manual

Page of 764
Document No. 10-300090, Issue 1
11-25
IP
ip irdp minadverinterval
Command Mode
Interface Configuration. 
Description
Sets the minimum interval in seconds between advertisements. The range is 
3 to 1799 seconds. The default setting is 450 seconds. Changing the 
maxadvertinterval value automatically changes the minadvertinterval value 
to three-quarters of the new value. 
The no command restores the default setting. 
Syntax
Systems
P550R, P580, P880, and P882. 
To Configure:
ip irdp minadvertinterval <irdpMinTimer>
To Restore Default:
no ip irdp minadvertinterval 
Table 11-13.  Parameters, Keywords, Arguments
Name
Definition
<irdpMinTimer>
The minimum interval in seconds, between advertisements. 
The range is 3 to 1799 seconds. 