Avaya 106760804 User Manual

Page of 764
Chapter 21
21-22
Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
set port intrusion-trap-timer 
Command Mode
Global Configuration.
Description
Sets the time interval at which intrusion traps are generated. The default 
setting for the intrusion trap timer is 1800 seconds (30 minutes). The valid 
range for the timer is 60 to 1800 seconds. 
Syntax
set port intrusion-trap-timer {<mod-num> | <mod-swport-range>}
[...,{<mod-num> | <mod-swport-range>}] <intrusion-trap-timer-value>
Systems
P550R, P580, P880, and P882. 
Table 21-20.  Parameters, Keywords, Arguments
Name
Definition
<mod-num>
Specifies the number of the module. 
<mod-swport-
range>
Specifies a range of switch ports. 
<intrusion-trap-
timer-value>
Time interval at which intrusion traps are generated. 
The default setting for the intrusion trap timer is 1800 
seconds (30 minutes). The valid range for the timer is 60 to 
1800 seconds.