Chapter 31
31-2
Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
clear temperatures
Command Mode
Global Configuration.
Description
Resets all configured warning and shutdown temperatures (in Celsius) to
their default values. The default values are listed in
their default values. The default values are listed in
Syntax
clear temperatures
Sample Output
The following example resets all configured warning and shutdown
temperatures to their default settings.
temperatures to their default settings.
(configure)#
clear temperatures
Systems
P550R, P580, P880, and P882.
Table 31-1. Default Shutdown and Warning Temperatures
Component
Shutdown
Upper
Warning
Warning
Lower
Warning
Warning
Low Limit
CPU Sensor
100°
85°
5°
0°
All others
65°
60°
5°
0°