Avaya 106760804 User Manual

Page of 764
Chapter 31
31-6
Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
show temperatures 
Command Mode
User.
Description
Displays the current temperatures and the configured temperature limits. 
There is no reverse mapping to this command. 
Syntax
show temperatures
Sample Output
The following example displays the current switch temperatures.
>
 show temperature
Systems
P550R, P580, P880, and P882. 
Slot 2 Sensor
Backplane Sensor
CPU Sensor
Shutdown (C)
65
65
100
Upper Warning (C)
60
60
85
Current
27
29
24
Lower Warning (C)
5
5
5
Low Limit (C)
0
0
0