Allied Telesis AT-PWR250 User Manual

Page of 92
Chapter 1: Overview
22
Figure 6. Removable and Non-removable Power Supply Modules in x610 
Switches
To summarize, a non-PoE+ x610 Series switch uses the AT-RPS3000 
Chassis as its active source of system power and its internal, non-
removable module as a redundant source. For a PoE+ x610 Series switch 
the reverse is true because its primary source of system power is its 
removable internal module and the redundant source is the power module 
in the AT-RPS3000 Chassis.
System power for PoE+ and non-PoE+ x610 Series switches is provided 
by all four RPS ports on the AT-RPS3000 Chassis. RPS 1 and 3 System 
ports provide only system power, and RPS 2 and 4 PoE+/System ports 
provide PoE+ power in addition to system power.
You may use any of the available power supply modules, listed in Table 1 
on page 19, 
to provide system power to the x610 Series switches. In fact, 
the modules, when installed in the AT-RPS3000 Chassis, can provide 
system power to two low-power switches at the same time, as explained in 
“Low-power and High-power Switches” on page 24.
The switch and chassis do not display the active or redundant status of a 
power supply module. You may use the LEDs and switch’s management 
software to determine whether a power module is operating correctly, but 
not whether it is the active or redundant system power for the switch.
PoE+ Power
The four x610 Series switches that support PoE+ on the twisted pair ports 
do not come with power supply modules. The modules have to be 
purchased separately. You may use any of the three modules in a PoE+ 
switch, although the AC AT-PWR250 Module does not provide PoE+ 
power, only system power. The AT-PWR800 and AT-PWR1200 Power 
Supply Modules provide 480 and 780 watts, respectively, of PoE+ power, 
in addition to system power.
As explained earlier in this Overview, there is no load sharing of system 
power between the power supplies in the switch and AT-RPS3000 
Chassis. Only one source is active while the other is held in a redundant 
state.
PO
WER SUPPL
Y
WARNING
This unit m
electric sho
unit.
AT
-P
W
R
8
00
100-240 VAC~5A MAX
PO
WER SUPPL
Y
WARNING
This unit ma
electric shoc
unit.
2158
DC OUT
FAULT
100-240 VAC~12A MAX
Non-removable Power Supply
Removable Power Supply
(PoE+ Switches)
(non-PoE+ Switches)