Allied Telesis AT-PWR250 User Manual

Page of 92
AT-RPS3000 Redundant Power Supply Installation Guide
45
Table 7 describes the Power Module Status LEDs.
Table 7.  Power Module Status LEDs
LED
State
Description
FAN
Green
The power module’s fans are operating 
normally.
Amber
One or both fans in the module have 
stopped or are operating below their 
normal operating speed.
Off
No power supply module is installed in the 
module slot.
DC OUT
Green
The DC output from the power supply 
module to the RPS ports is within the 
normal operating range.
Amber
The DC output from the power supply 
module is below the normal operating 
range, either because the module is 
failing or the input voltage from the AC 
power source is below the normal 
operating range.
Off
The module is not receiving any AC 
power or the slot is empty.
TEMP
Green
The temperatures inside the power supply 
modules are in the normal operating 
range.
Amber
One of the power supply modules is 
experiencing an increase in temperature 
that exceeds the normal operating range. 
The affected module is continuing to 
provide system power to its two RPS 
ports, but has stopped providing PoE+ 
power to the PoE+/System port. To 
determine which power supply in the 
chassis is overheating, use the SHOW 
SYSTEM ENVIRONMENT command in 
the management software on the x610 
Series switch.