Verify that the power supply module that is suppose to be delivering 
the PoE+ power from the chassis is either the AT-PWR800 or 
AT-PWR1200 Module. The AT-PWR250 Module do not support PoE+ 
power.
Check the FAN LED for the power supply module, in the LED panel. If 
the LED is amber, one or both fans in the module are not functioning 
properly. If this occurs, the module continues to provide system power 
on both of its RPS ports, but stops providing PoE+ power on the RPS 
PoE+/System port.
Check the TEMP LED in the LED panel. If the LED is amber, the power 
module may be overheating. When this occurs, the module continues 
to provide system power on both of its RPS ports, but stops providing 
PoE+ power on the RPS PoE+/System port.