Panasonic PT-F200U User Manual

Page of 62
Care and Replacement
E
NGLISH - 41
Maintenance
J
Resetting the FILTER 
REMAINING
1. Turn on the projector and display the FILTER 
REMAINING in OPTION menu. Press the ENTER 
button for 3 seconds and the confirmation screen 
will be displayed. 
2. Press I to select OK and press the ENTER 
button to reset FILTER REMAINING to “0”. 
J
Before replacing the Lamp unit
 
Switch off the MAIN POWER and disconnect the power plug from the wall socket.
 
Wait for more than 1 hour and make sure the Lamp unit and the surroundings are cooled enough.
 
Prepare a Phillips-head screwdriver.
 
Contact an Authorized Service Center to purchase a replacement Lamp unit (ET-LAF100).
 
When the projector is mounted in the ceiling, do not work directly under the projector or put your face closer 
to the projector.
J
When to replace the Lamp unit
The Lamp unit is consumable and the brightness decreases by duration of usage. The LAMP indicator will 
inform you of the replacement timing at 4 800 hours, and at 5 000 hours, the projector will be turned off. Those 
figures are rough guidance and might be shortened by the usage conditions, characteristics of the Lamp unit
environmental conditions, and so on. You can check the duration of usage time using LAMP RUNTIME in the 
OPTION menu.
RESET A REMAIN OF A FILETER.
OK
CANCEL
SELECT
ENTER
RETURN
FILTER REMAINING
Replacing the Lamp unit
NOTE:
• Prior to replacing the lamp unit, allow it to cool down to prevent the risk of burns, damage and other hazards.
• Do not attempt replacement with an unauthorized lamp unit.
Indication
On screen
LAMP indicator
Over 4 800 hours
REPLACE LAMP” is displayed on the 
upper left of the screen for 30 seconds.
Illuminates RED.
Over 5 000 hours
REPLACE LAMP” is displayed on the 
upper left of the screen, and it will stay until 
you respond.
To clear the screen, press any button.
NOTE:
• The guide times, 4 800 and 5 000 hours, are rough estimates based on certain conditions and is not a guaranteed time.
• For more information about the Lamp unit, such as guaranteed time, see the instructions which is provided with the 
Lamp unit.
REPLACE LAMP