Panasonic PT-EZ770ZU User Manual
![Panasonic](https://files.manualsbrain.com/attachments/8f677e63fb64cbb6c62d09e6242996e7631380a8/common/fit/150/50/34d700d3fb727c767799b2da5cc474b219c0a4312e9e3044c99491a2fb9a/brand_logo.png)
Chapter 4 Settings — [P IN P] menu
ENGLISH - 101
14) If [CLOCK PHASE] is selected in Step 8), press qw to make adjustment.
15) Press as to select [FRAME LOCK].
16) Press qw to switch the item.
15) Press as to select [FRAME LOCK].
16) Press qw to switch the item.
[MAIN WINDOW]
Set frame lock to the input signal set in the main window.
[SUB WINDOW]
Set frame lock to the input signal set in the sub window.
17) Press as to select [TYPE].
18) Press qw to switch the item.
18) Press qw to switch the item.
[MAIN WINDOW]
The main window has display priority.
[SUB WINDOW]
The sub window has display priority.
Note
f
The P IN P function may not be available for some signals being input or terminals being selected. Refer to “Two-window display
combination list” (x page 146) for details.
f
The main window setting values are applied to image adjustment values such as [PICTURE MODE], [GAMMA], and [COLOR
TEMPERATURE].
f
On the normal screen (when no menu is displayed), press as to switch the size and position of the main window and sub window while P
IN P is operating.
f
If the signals from the <RGB 1 IN> or <RGB 2 IN> terminal are input to either the main window or the sub window, and those input signals
are analog RGB or YC
B
C
R
/YP
B
P
R
signals, the signals are output from the <MONITOR OUT> terminal. If input combination of the main
window and sub window is RGB1 and RGB2, the signals of the main window take priority for output.