Panasonic PT-DW11KU User Manual

Page of 187
Chapter 5Maintenance — Lamp/temperature/filter indicators
156 - ENGLISH
Temperature indicator <TEMP>
Indicator status
Lighting in red
Flashing in red
(2 times)
Flashing in red
(3 times)
Status
Warm-up status
Internal temperature is high 
(warning).
Internal temperature is high 
(standby status).
The cooling fan has 
stopped.
Cause
 
f
Did you turn on the power 
when the temperature 
was low (around 0 °C 
(32 °F))?
 
f
Is the air intake/exhaust port blocked?
 
f
Is the room temperature high?
 
f
Is the filter indicator <FILTER> lit?
Solution
 
f
Wait at least five minutes 
in the current status.
 
f
Install the projector in a 
location with an ambient 
temperature of 0 °C 
(32 °F) to 45 °C (113 °F)
*1
.
 
f
Remove any objects that are blocking the air intake/
exhaust port.
 
f
Install the projector in a location with an ambient 
temperature of 0 °C (32 °F) to 45 °C (113 °F)
*1
.
 
f
Do not use the projector at high altitudes of 2 700 m 
(8 858') or higher above sea level.
 
f
Clean or replace the air filter unit. (x page 157)
 
f
Turn the <MAIN POWER> 
switch to <OFF> 
(x page 55), and 
consult your dealer.
*1  When using the projector at high altitudes (1 400 m (4 593') or higher – lower than 2 700 m (8 858') above sea level), the operating environment 
temperature should be between 0 °C (32 °F) and 40 °C (104 °F).
If you use the Smoke cut filter, the operating environment temperature should be between 0 °C (32 °F) and 35 °C (95 °F). However, it cannot be 
used at high altitudes.
If you use the Replacement lamp unit (for portrait mode), the operating environment temperature should be between 0 °C (32 °F) and 40 °C 
(104 °F) when using the projector at elevations lower than 1 400 m (4 593') above sea level, and between 0 °C (32 °F) and 35 °C (95 °F) when 
using the projector at high altitudes. If you use the Smoke cut filter together, the operating environment temperature should be between 0 °C (32 °F) 
and 30 °C (86 °F).
Note
 
f
If the temperature indicator <TEMP> is still lit or flashing after taking the preceding measures, ask your dealer for repair.
 
f
If you use the projector with the following two settings made, the light output may drop by approx. 20 % to protect the projector when an 
ambient temperature becomes 40 °C (104 °F) or higher (35 °C (95 °F) or higher if [HIGH ALTITUDE MODE] is set to [ON], or if the Smoke 
cut filter is used).
 
g
When [LAMP SELECT] is set to [DUAL] from the menu
 
g
When [LAMP POWER] is set to [HIGH], [MIDDLE], or [NORMAL] from the menu
Filter indicator <FILTER>
Indicator status
Lighting in red
Flashing in red
Status
The filter is clogged.
The temperature inside or outside the projector is abnormally high.
The air filter unit is not 
attached.
Cause
 
f
Is the air filter unit dirty?
 
f
Is the air intake/exhaust 
port blocked?
 
f
Is [HIGH ALTITUDE 
MODE] set correctly?
 
f
Is the air filter unit 
attached?
Solution
 
f
Clean or replace the air 
filter unit. (x page 157)
 
f
Remove any objects that 
are blocking the air intake/
exhaust port.
 
f
When using the projector 
at high altitudes between 
1 400 m (4 593') or higher 
and lower than 2 700 m 
(8 858') above sea level, 
set [HIGH ALTITUDE 
MODE] (x page 109) to 
[ON].
 
f
Do not use the projector 
at high altitudes of 
2 700 m (8 858') or higher 
above sea level.
 
f
Attach the air filter unit.
Note
 
f
If the filter indicator <FILTER> is still lit or flashing after taking the preceding measures, ask your dealer for repair.
 
f
If the filter is clogged, only one lamp may light even when [LAMP SELECT] is set to [DUAL]. By cleaning the air filter unit or replacing it with 
a new one, the lamp will light properly.