PJLink protocol
The network function of the projector supports PJLink class 1, and the PJLink protocol can be used to perform 
projector setting and projector status query operations from a computer.
Control commands
 
J
The following table lists the PJLink protocol commands that can be used to control the projector.
Command
Control details
Notes
POWR
Power supply control
Parameters
0 = Standby
1 = Power ON
POWR ?
Power supply status query
Parameters
0 = Standby    1 = Power ON
2 = Cool-down in progress    3 = Warm-up in progress
INPT
Input selection
Parameters
11 = RGB1    12 = RGB2    21 = VIDEO
22 = S-VIDEO    31 = DVI-D    32 = HDMI
33 = SDI (PT-DZ110XE/PT-DS100XE only)
INPT ?
Input selection query
AVMT
Shutter control
Parameters
30 = Shutter mode off (picture mute canceled)
31 = Shutter mode on (picture mute)
AVMT ?
Shutter mode query
ERST ?
Error status query
Parameters
1st byte : Indicates fan errors, range 0 - 2
2nd byte : Indicates lamp errors, range 0 - 2
3rd byte : Indicates temperature errors, range 0 - 2
4th byte : Indicates cover open errors, range 0 - 2
5th byte : Indicates filter errors, range 0 - 2
6th byte : Indicates other errors, range 0 - 2
Definitions for each value from 0 to 2 are as follows.
0 = No error known    1 = Warning    2 = Error
LAMP ?
Lamp status query
Parameters
1st digits (1 - 5 digits) : Lamp 1 cumulative operating time
2nd digit : 0 = Lamp 1 off, 1 = Lamp 1 on
3rd digits (1 - 5 digits) : Lamp 2 cumulative operating time
4th digit : 0 = Lamp 2 off, 1 = Lamp 2 on
INST ?
Input selection list query
The following are returned as parameters.
“11 12 21 22 31 32” (PT-DW90XE only)
“11 12 21 22 31 32 33” (PT-DZ110XE/PT-DS100XE only)
NAME ?
Projector name query
The name set for [PROJECTOR NAME] in [NETWORK SETUP] is 
returned.
INF1 ?
Manufacturer name query “Panasonic” is returned.
INF2 ?
Model name query
“DZ110”, “DS100” or “DW90” is returned.
INF0 ?
Other information query
Information such as version number is returned.
CLSS ?
Class information query
“1” is returned.
PJLink security authorization
 
J
When using PJLink with security authorization, either of the password set for administrator privileges and the 
password set for user privileges with Web browser control can be used as the password for PJLink.
When using PJLink without security authorization, set use without the password for administrator privileges 
and the password for user privileges of Web browser control.
For specifications regarding PJLink, refer to the Japan Business Machine and Information System 
 
z
Industries Association website.
URL http://pjlink.jbmia.or.jp/