Control commands via LAN
 
J
When WEB Control administrator rights password is set (Protect mode)
<Connection method>
Obtain the IP address and port number (Initial set value = 1024) of the projector and 
1 ) 
make a request for connection to the projector.
You can obtain both IP address and port number from the menu screen of the projector.
IP address :  Obtain from MAIN MENU ⇒ [NETWORK] ⇒ [NETWORK STATUS]
Port No. : 
Obtain from MAIN MENU 
⇒ [NETWORK] ⇒ [NETWORK CONTROL] ⇒ [COMMAND PORT]
There is a response from the projector.
2 ) 
Response data
Data section
Blank
Mode
Blank
Random number  
section
Termination 
symbol
“NTCONTROL”
(ASCII string)
‘  ’
0x20
‘1’
0x31
‘  ’
0x20
“zzzzzzzz”
(ASCII code hexadecimal 
number)
(CR)
0x0d
9 bytes
1 byte
1 byte
1 byte
8 bytes
1 byte
Mode :   1 = Protect mode
Generate a 32-byte hash value from the following data using MD5 algorithm.
3 ) 
“xxxxxx:yyyyy:zzzzzzzz”
xxxxxx
 :  Administrator rights user name for WEB CONTROL  
(Default user name is “admin1”)
yyyyy : 
Password of above administrator rights user  
(Default password is “panasonic”)
zzzzzzzz :  8-byte random number obtained in Step 2)
<Command transmission method>
Transmit using the following command format.
Transmitted data
Header
Data section
Termination 
symbol
Hash value
(See above  
<Connection method>)
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
32 bytes
1 byte
1 byte
Undefined length
1 byte
Receive data
Header
Data section
Termination 
symbol
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
1 byte
1 byte
Undefined length
1 byte
Error response
Error message
Termination symbol
“ERR1”
“ERR2”
“ERR3”
“ERR4”
“ERR5”
“ERRA”
Undefined control command
Out of parameter range
Busy state or no-acceptable period
Timeout or no-acceptable period
Wrong data length
Password mismatch
(CR)
0x0d
4 bytes
1 byte