Panasonic PT-EX12KU User Manual

Page of 119
Technical Information
106 - ENGLISH
Appendix
Pin assignments and signal names
<SERIAL IN> terminal
Outside view
Pin No.
Signal name
Details
(1)
(5)
(6)
(9)
(1)
NC
(2)
TXD
Transmitted data
(3)
RXD
Received data
(4)
NC
(5)
GND
Ground
(6)
NC
(7)
CTS
Connected internally
(8)
RTS
(9)
NC
<SERIAL OUT> terminal
Outside view
Pin No.
Signal name
Details
(1)
(5)
(6)
(9)
(1)
NC
(2)
RXD
Received data
(3)
TXD
Transmitted data
(4)
NC
(5)
GND
Ground
(6)
NC
(7)
RTS
Connected internally
(8)
CTS
(9)
NC
Transmission conditions
Signal level
RS-232C-compliant
Character length
8 bit
Sync. method
Asynchronous
Stop bit
1 bit
Baud rate
19 200 bps
*1
X parameter
None
Parity
None
S parameter
None
*1:  Fixed to 9 600 bps when [AMX D. D.] is set to on.
Basic format
Transmission from the computer begins with STX, then the ID, command, parameter, and ETX are sent in this 
order. Add parameters according to the details of control.
E\WHV
,'FKDUDFWHUVE\WHV
6HPLFRORQE\WH
&RORQ
E\WH
,'FKDUDFWHUV
E\WHV
3DUDPHWHU
XQGHILQHGOHQJWK
(QG
E\WH
6WDUWE\WH
==WR
,'GHVLJQDWH
*1:  When sending commands without parameters, a colon (:) is not necessary.