J
Transmission from the computer begins with STX, then the command, parameter, and ETX are sent in this 
order. Add parameters according to the details of control.
STX
C1 C2 C3
P1 P2
Pn
ETX
When sending commands without parameters, a colon (:) is not necessary.
½
Basic format (with sub command)
 
J
STX
C1 C2 C3
ETX
S1
S2
S3
S4
S5
E
P1
P2
P3
P4
P5
P6
When transmitting a command which does not need a parameter, the operation (E) and parameter are not 
½
necessary.
End  
(1 byte)
Parameter  
(undefined length)
Colon  
(1 byte)
3 command 
characters  
(3 bytes)
Start  
(1 byte)
Parameter (6 bytes)
Symbol “+” or “-” (1 byte) and set value or 
adjustment value (5 bytes)
Operation (1 byte)
“=” (Value specified using parameter is set)
Same as basic format
Sub command (5 bytes)
Serial control