Panasonic PT-RW330U User Manual

Page of 128
Chapter 5  Maintenance — Light source/temperature indicator
ENGLISH - 109
Light source/temperature indicator
Managing the indicated problems
If a problem should occur inside the projector, the light source indicator <LIGHT>/temperature indicator <TEMP> will inform you by lighting or 
flashing.
Check the status of the indicators and manage the indicated problems as follows.
Attention
 
f
When switching off the projector to deal with problems, make sure to follow the procedure in “Switching off the projector” (x page 34).
 
f
Check the status of the power supply with the power indicator <ON (G)/STANDBY (R)>. (x page 32)
/LJKWVRXUFHLQGLFDWRU/,*+7!
3RZHULQGLFDWRU21*67$1'%<5!
7HPSHUDWXUHLQGLFDWRU7(03!
Light source indicator <LIGHT>
Indicator status
Lighting in red
(Projection status)
Flashing in red
(2 time)
Flashing in red
(3 time)
Status
The light source may not light normally. The light source does not turn on or turns off unexpectedly.
Cause
Solution
Set the <MAIN POWER> switch to <OFF> (x page 34), and turn on the power again.
Note
 
f
If the light source indicator <LIGHT> still lights or flashing after taking the preceding measures, set the <MAIN POWER> switch to <OFF> 
(x page 34), and ask your dealer to repair the unit.