2.130. Query Date 
Hexadecimal 02h 51h 47h 44h 
03h 
Character    Q G D   
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h 
*y1 
*y2 
*y3 
*y4 
*m1 
*m2 
*d1 
*d2 *w 03h 
Character 
 
 
 
 
 
 
 
 
 
 
 
Parameters (*1, *2, *3, *4, *5, *6) 
*y1 - *y4: Year (4 digits) 
*m1, *m2: Month (2 digits) 
*d1, *d2: Day (2 digits) 
*w: Day of the week (Mon = 1, Tue = 2, Wed = 3, Thu = 4, Fri = 5, Sat = 6, Sun = 7) 
Set it by UTC (Coordinated Universal Time). 
Example: Tuesday, April 1, 2008 
 
*y1 *y2 *y3 *y4 *m1 
*m2 
*d1 *d2  *w 
Hexadecimal 32h 30h 30h 38h 30h 34h 30h 31h 31h 
Character 2 0 0 8 0 4 0 1 2 
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
 
 
 
 
 
2.131. Query Time 
Hexadecimal 02h 51h 47h 54h 
03h 
Character  Q G T  
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h *h1  *h2 *m1 *m2 *s1  *s2  03h 
Character 
 
 
 
 
 
 
 
 
Parameters 
*h1, *h2: Hour (2 digits) 
*m1, *m2: Minute (2 digits) 
*s1, *s2: Second (2 digits) 
Set it by UTC (Coordinated Universal Time). 
Example: 3 seconds at 3:45 p.m. 
 *h1 
*h2 
*m1 
*m2 
*s1 *s2 
Hexadecimal  31h 35h 34h 35h 30h 33h 
Character  1 5 4 5 0 3 
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
 
 
 
 
 
2.132. Query RUNTIME - LAMP 
Hexadecimal 02h 51h 24h 4Ch 
03h 
Character  Q $ L  
Response (Callback) 
In the period when the command can be accepted 
Hexadecimal 02h *1 *3 *5 *7 03h 
Character 
  *2 *4 *6 *8   
Acceptability 
SECURITY STANDBY NO 
SIGNAL  AV MUTE  REMOTE 
 
 
 
 
 
Parameters (*1, *2, *3, *4, *5, *6) 
 
0 h 
1 h 
Hexadecimal 30h 30h 30h 30h 30h 30h 30h 31h 
Character 0 0 0 0 0 0 0 1 
 
9998 h 
9999 h 
Hexadecimal 39h 39h 39h 38h 39h 39h 39h 39h 
Character 9 9 9 8 9 9 9 9 
Note: 
• 