Promise Technology m210p User Manual

Page of 262
Chapter 4: Management with WebPAM PROe
101
To Migrate an existing disk array: 
1.
Click the Subsystem 
 icon in Tree View. 
2.
Click on the Disk Arrays 
 icon. 
3.
Click on the Disk Array 
 icon. 
4.
Click the Background Activities tab in Management view. 
5.
From the dropdown menu on the Background Activities tab, select Start 
Migration
6.
Under Capacity Usage, if there is more than one Disk Array, click on the one 
you want to Migrate. 
7.
Select a new RAID Level, if desired. 
8.
To expand the disk array's capacity, check the Expand Capacity box. 
9.
If you checked the Expand Capacity box, enter a number into the Capacity 
field and select the appropriate unit of measure (MB, GB, TB). 
10. Click on the Update button.
The information under Capacity Usage changes to reflect your choices. 
11. If you agree with the changes, click on the Next button. 
12. Click on the Submit button to begin Migration. 
Disk Array Rebuild
When you rebuild a disk array, you are actually rebuilding the data on one disk 
drive. Normally, a disk array would rebuild itself using a hot disk drive, after going 
Critical. However, if the Auto Rebuild function is disabled or no spare drives are 
available, you must initiate the procedure.
To enable Auto Rebuild, see “Background Activities” on page 50.
To create a spare drive, see “Create Spare Drive” on page 113.
For more information, see “Hot Spare Drive(s)” on page 194.
Notes
You can add physical drives to a RAID 50 array but you 
cannot change the number of axles.
If you add an odd number of physical drives to a RAID 10 
array, it will become a RAID 1E array by default.