6
Before Installing Your Unifi 45 Projector Retrofit Kit
99-00881-20 A0
Environmental Requirements
Before installing your Unifi 45 projector retrofit kit, review the following environmental requirements.       
CAUTION
Never operate this unit immediately after moving it from a cold location to a warm location. 
When the unit is exposed to such a change in temperature, moisture might condense 
 
on the lens and crucial internal parts. To prevent the unit from possible damage, do not use it 
 
for at least two hours when there is an extreme or sudden change in temperature.
In a high altitude location where air is thin, cooling efficiency is reduced. 
 
Therefore, use the projector with fan mode set to High.
Do not place the unit in hot locations, such as near heating equipment, which could cause 
 
a malfunction and shorten the life of the projector.
Environmental Requirement
Parameter
Operating Temperature
41°F to 95°F (5°C to 35°C) from sea level to an altitude 
 
up to 6000' (0 m to 1829 m)
41°F to 86°F (5°C to 30°C) from 6000' to 9800' 
 
(1829 m to 2987 m)
Storage Temperature
-40°F to 122°F (-40°C to 50°C)
Humidity
30–70% relative humidity, non-condensing
Water and Fluid Resistance
Intended for indoor use. SMART Board interactive whiteboard 
systems do not meet any salt-spray or water ingress 
requirements.
Do not pour or spray liquids directly onto the interactive 
whiteboard, the Unifi projector or any of its sub-components. 
These liquids might get into areas where they could damage 
sensitive electronic components.
Refer to page 31 for detailed instructions on cleaning 
 
your system’s components.
Dust and Scratching
For use in office and classroom environments
Not for industrial use, where heavy dust and pollutants can 
cause malfunctions or impaired operation
Designed for pollution degree 1 (P1) as per EN61558-1, which 
is defined as “No pollution or only dry non-conductive pollution”
Electrostatic Discharge (ESD)
EN61000-4-2 severity level 4 for direct and indirect ESD
No malfunction or damage up to 8kV (both polarities) 
 
with a 330 ohm, 150 pF probe (air discharge)
Unmated connectors meet no malfunction or damage 
 
up to 4kV for direct (contact) discharge.
Conducted and Radiated Emissions
EN55022/CISPR 22, Class A