Graco 114903 User Manual

Page of 6
 
2
308953N
Installation Instructions
Reference letters used in the following instructions, refer 
to F
IG
. 2.
Group injectors to minimize feed line length.
Install injectors in locations that allow easy and safe 
servicing access.
Install injectors in areas that minimize accidental 
injector damage by moving equipment.
Injector outputs can be combined for a common 
bearing point with a large grease requirement but 
the output for a single injector cannot be split into 
multiple bearing points.
Graco recommends using steel tubing instead of 
pipe and hose for supply lines when possible. Pipe 
is often contaminated with scale and requires 
proper cleaning prior to use. Hose lines expand 
under pressure which leads to longer pump cycle 
time.
1. Relieve pressure. See Pressure Relief Procedure
in the pump instruction manual included with your 
automatic lubrication system.
2. Install injectors on a flat, hard surface using mount-
ing brackets (a).
3. Connect fluid supply line (c) to injectors.
4. Connect lube point feed lines (b).
5. Flush the system with low viscosity oil or mineral 
spirits to remove contamination introduced during 
installation.
6. Use a purge gun or run the pump until clean lubri-
cant is dispensed at the end of each feed line to 
purge the system of flushing fluid or air.
7. Run the system at full output and verify that all injec-
tors are cycling.
8. Adjust injector volume output. (See Volume Adjust-
ment page 4.)
9. Connect feed lines to lubrication points.
NOTICE
To prevent rupturing supply lines due to over-pres-
surizing the components, only use supply lines and 
fittings that meet or exceed the pressure rating of the 
injectors.