Addtron Technology PR0017 User Manual

Page of 6
 
Mercury 6-5 M/E Installation guide 
Mercury Hub User Guide 
Specification 
 
Power requirements: 
 
Supply Voltage Range:   
100 - 240 Vac ±10% (Mains version) 
Supply Frequency: 
 
50 - 60 Hz (Mains version) 
 
 
 
OR 
2 x Mercury Controllers connected to ports 1 and 2 
Maximum supply current: 
500 mAmps  
Typical supply current:   
<100 mAmps 
Operating temperature range: 
+5
0
C to +50
0
Operating Humidity: 
 
80% maximum 
Storage temperature range:   
-20
0
C to +65
0
Environmental:   
 
Indoor use at altitudes up to 2000m, Pollution Degree 1,  
    Installation 
Category 
II. 
 
 
 
 
Voltage fluctuations not to exceed ±10% of nominal voltage 
Size: 
 
 
 
300mm (L) x 35mm (H) x 110mm (W)  
Weight: 
   300 
Grams 
Safety: 
   EN61010 
EMC:   
 
 
EN61326; 1997 +Amdt. A1; 1998 
Ventilation: 
 
 
There is no requirement for forced cooling ventilation 
Class 2 Insulation: 
 
No protective Earth is required and none should be fitted. 
 
The host equipment must provide a suitable external over-current protection device such as: - 
Fuse:   
 
 
1A 240 Vac Antisurge (T) HRC conforming to IEC 60127 
Or MCB: 
 
 
1A, 240 VAC Type C conforming to BS EN 60898 
 
 
Mounting 
 
There is a fixing lug at each end of the Hub, with hole centres 317 mm apart. Use typically Number 6  x 1” 
Pan head screw with 6mm washer, torque down to 1.5 Newton metres. 
 
RS232 Cable Lengths 
 
Port number 
Main Powered Hub 
Mercury Powered Hub 
15 metres 
5 metres 
15 metres 
5 metres 
15 metres 
15 metres 
15 metres 
15 metres 
15 metres 
15 metres 
15 metres 
15 metres 
15 metres 
15 metres 
15 metres 
15 metres 
15 metres 
15 metres 
15 metres 
15 metres 
 
Ethernet Cable lengths 
 
Port number 
Main Powered Hub 
Mercury Powered Hub 
Refer to Cat5 standard 
Refer to Cat5 standard 
Refer to Cat5 standard 
Refer to Cat5 standard 
Uplink 
Refer to Cat5 standard 
Refer to Cat5 standard 
 
 
Ensure that all power is 
 
 
 
switched off before   
installing or maintaining 
this product 
  
Revision 1.5 
Page 6 of 6