TP-LINK TL-SG3424P User Manual

Page of 292
 
 
Switch B is connecting to PC B and Server A; 
 
PC A and Server A is in the same VLAN; 
 
PC B and Server B is in the same VLAN; 
 
PCs in the two VLANs cannot communicate with each other. 
 
Network Diagram 
 
 
Configuration Procedure 
 
Configure Switch A 
Step 
Operation 
Description 
 Configure the 
Link Type of the 
ports 
Required. On 
VLAN→802.1Q VLAN →Port Config page, configure 
the link type of Port 2, Port 3 and Port 4 as ACCESS, TRUNK and 
ACCESS respectively 
 Create VLAN10  Required. On 
VLAN→802.1Q VLAN→VLAN Config page, create a 
VLAN with its VLAN ID as 10, owning Port 2 and Port 3. 
 Create VLAN20  Required. On 
VLAN→802.1Q VLAN→VLAN Config page, create a 
VLAN with its VLAN ID as 20, owning Port 3 and Port 4.   
 
Configure Switch B 
Step 
Operation 
Description 
 Configure the 
Link Type of the 
ports 
Required. On 
VLAN→802.1Q VLAN →Port Config page, configure 
the link type of Port 7, Port 6 and Port 8 as ACCESS, TRUNK and 
ACCESS respectively.   
 Create VLAN10  Required. On 
VLAN→802.1Q VLAN→VLAN Config page, create a 
VLAN with its VLAN ID as 10, owning Port 6 and Port 8. 
 Create VLAN20  Required. On 
VLAN→802.1Q VLAN→VLAN Config page, create a 
VLAN with its VLAN ID as 20, owning Port 6 and Port 7. 
80