INSTALLATION
 
Page 3-2
2.
Attach the strain relief bracket to the bottom of the TRXI as shown 
in Figure 3-1.
Figure 3-1. Attaching the Strain Relief
 
3.3
INSTALLING THE TRXI
 
The TRXI can be rack mounted, wall mounted, or placed on any 
horizontal surface. Select one of the following subsections and perform 
the steps that are applicable for your installation. If you decide not to 
install the TRXI in a 19-inch rack, the following requirements must be 
met when selecting a location.
 
Note
 
: Be sure that the location selected is within reach of the network 
cabling.
 
An unrestricted free surface area at least 21 inches wide, 18 
inches deep and 6 inches high is needed.
A single phase 85 to 264 Vac, 15A, grounded power receptacle 
must be located within 7 feet of the site.
If a shelving unit is to be used, it must be able to support 30 
pounds of static weight.
The temperature for the selected location must be maintained 
between 5
 
°
 
 and 50
 
°
 
C, and less than 10
 
°
 
C per hour temperature 
change.
TRXI-24 
 TOKEN RING HUB 
WITH
 LANVIEW®