Cabletron Systems STS16-20D User Manual

Page of 258
229
Cable and Pin Information
SmartStack STS16-20D/STS16-20R Token Ring Switches Installation and User Guide
Appendix B.  Cable and Pin Information
This appendix provides information on cables that can be used with the SmartStack 
STS16-20D/STS16-20R. It also provides minimum pin-out information to be used 
to verify that the cables are correctly wired.
Connecting to the Out-of-Band Management Port
Table 16 lists the type of cables that are used when connecting to the OBM port 
(labeled MANAGEMENT) on the front panel of the switch. 
Out-of-Band Management Port and Cable Pin-Outs 
The switch’s Out-of-Band Management (OBM) port (labeled MANAGEMENT on 
the front panel) is an TIA/EIA-232 port wired as a DTE. For this reason, you cannot 
use a straight-through modem cable to directly connect a terminal to the 
MANAGEMENT port.
For a terminal connection, you can use either a null-modem cable or a modem cable 
with a null-modem adapter attached. For a modem connection, you can use a 
standard modem cable.
This section provides pin-out information for the cables you can use to connect to 
the MANAGEMENT port.
Cable Function
Cable Type or Cable Solution
Connect a modem to the 
MANAGEMENT port.
Connect one end of a straight-through, 
TIA/EIA- 232 modem cable to the 
MANAGEMENT port and the other end to the 
modem.
Connect a PC or other DTE 
device to the 
MANAGEMENT port.
Connect one end of a crossover, TIA/EIA-232 
cable to the MANAGEMENT port and the other 
end to the PC or DTE device
or
attach a null-modem adapter to the 
MANAGEMENT port. Then, attach a straight-
through modem cable to the null-modem 
adapter.
Table 16.  Connecting to the Management Port