Cabletron Systems STS16-20R User Manual

Page of 258
126
SmartStack STS16-20D/STS16-20R Token Ring Switches Installation and User Guide
Switch Configuration
Address Aging
You can set the per-port aging value using the Address Aging menu. The following 
describes the types of address aging.
There are two types of aging:
Port aging
— Any address in a port's address table that has not been active for a port's 
configured aging time will be removed from the port’s table
— Set at the Port Address Table Aging menu
Master Table aging
— Addresses that are in the master address table, but not in any port address 
table, will be removed from the master address table after the system aging 
time
— Set at the Master Address Table Aging menu
There are two levels to set for the port and master aging tables:
Time Interval Aging
 is a time limit, in minutes, which will drop older addresses 
after the selected time.
Automatic On-Demand Aging
 stores addresses until reaching maximum capacity of 
the table, then deletes addresses, (in the following specific order) down to a selected 
percentage level and continues to cycle in the same manner.
Random remote addresses
Sequential remote addresses
— sequentially aged from the top of the Address Aging table to the bottom of 
the table
Random local addresses
Sequential local addresses
More information on address aging and the address aging screens is presented in 
the following sections.