Cabletron Systems STS16-20R User Manual

Page of 258
68
SmartStack STS16-20D/STS16-20R Token Ring Switches Installation and User Guide
Installation
Table 12.  Inter-box Parameters
Checking the Installation
The SmartStack STS16-20D/STS16-20R performs a diagnostic self-test during the 
power on cycle. From a management console, check that the switch lists the 
SmartStack STS-LM port along with the switch ports and that there are no error 
messages. The SmartStack STS-LM port will be listed as port 29.
If, after installation, there is poor system performance or the SmartStack STS-LM 
module does not work at all, remove the module and check for any damaged or bent 
connector pins. You may need a bright light to see inside the stacker slot to check 
for bent pins. Also, verify that the module is set firmly in place.
Menu
Parameter
IP Configuration
IP Address, IP Gateway, IP Subnet, IP State
Spanning Tree 
Protocol
STP Enabling/Disabling, STP Switch Priority, STP 
Maximum Aging, STP Hello Time, STP Forward Delay
Virtual LAN 
Name 
Configuration
Changing VLAN names
Password
System password
Console 
Configuration
Console Time-out
Telnet 
Configuration
Number of Allowed Telnet Sessions, Disallow New Telnet 
Sessions
TFTP Download
TFTP Server Address, Download Domain, Download 
Filename
Switch/Stack 
Information
Stack Timeout, System Name, System Contact, System 
Location
SNMP 
Configuration
Send Authentication Traps, changing the Trap table in any 
way, changing the Community Name table in any way