REQUIREMENTS/SPECIFICATIONS
 
Page 2-14
 
TPIM-F2
 
The TPIM-F2 shown in Figure 2-6 is an ST connector that supports 
Multimode fiber Optic cabling. 
Figure 2-6. The TPIM-F2
 
Note
 
: The transmitter power levels and receive sensitivity levels given 
are Peak Power Levels after optical overshoot. A Peak Power Meter must 
be used to correctly compare the values given to those measured on any 
particular port. If Power Levels are being measured with an Average 
Power Meter, then 3 dBm must be added to the measurement to correctly 
compare those measured values to the values listed (i.e. -30.5 dBm 
peak=-33.5 dBm average).
 
Parameter
Typical
Worst
Worst Case  Typical
Value
Case
Budget
Budget
 
Receive 
Sensitivity:
-30.5 dBm -28.0 dBm    
 —
 
 —
Peak Input 
Power:
-7.6 dBm
-8.2 dBm
   
 —
 
 —
Transmitter Power 
50/125 
 
µ
 
fiber:
-13.0 dBm -15.0 dBm 13.0 dB
17.5 dB
62.5/125 
 
µ
 
fiber:
-10.0 dBm -12.0 dBm 16.0 dB
20.5 dB
100/140 
 
µ
 
fiber:
-7.0 dBm
-9.0 dBm
19.0 dB
23.5 dB
Error Rate:
Better than 10
 
-10
TPIM-F2
LNK
RX
TX