Status
Display only. Shows the current status of the virtual port. 
MTU
You can use only one value as MTU.
Default: 1500
Max Broadcast Rate (frames/sec)
Sets the maximum broadcast frame rate; possible values are 0 to 5000 frames/sec 
or Disabled. If enabled, this will limit the amount of broadcast frames being 
forwarded from the TS side of the virtual port to the switch.
Default: Disabled
Value
Meaning
Admin down
The port or virtual port is disabled.
Waiting for port up
The virtual port is waiting for the port to 
come up.
Up
The virtual port is up but not 
forwarding.
Forwarding
The virtual port is up and forwarding.
Temporary down
The virtual port is currently down, 
because the port is temporarily down.
Table 5.  Translational Switch Virtual Port Status
MTU configured
Actual TS frame size
LF bits
1500
1558
001