Cabletron Systems DLE32-MA User Manual

Page of 202
General Configuration Screen
DLE22-MA,DLE32-MA,DLE23-MA and DLE33-MA User’s Guide
5-49
5.15.12 Changing the Com Port Application
After enabling the COM port as described in Section 5.15.11, you can 
select one of the applications supported by the COM port: LM, and UPS. 
The default application is LM.
To change the COM port application: 
1.
Use the arrows keys to highlight the Application field.
2.
Use the SPACE bar or BACKSPACE to step through the available 
settings until the operation you require appears. Table 5-3 lists the 
available settings and their corresponding applications. 
3.
Press ENTER to accept the application.
4.
Use the arrow keys to highlight SAVE at the bottom of the screen, then 
press the ENTER key.
5.
When the message “SAVED OK” appears, the edits you made are 
saved. 
!
Exiting without saving causes the message “NOT SAVED -- 
PRESS SAVE TO KEEP CHANGES” to appear. Exiting without 
saving causes all edits to be lost.
Table 5-3. COM Port Application Settings
Setting
Application
LM
Local Management Session
UPS
APC Power Supply SNMP Proxy
!
When the COM port is configured to perform the UPS 
application, all future Local Management connections must be 
made by establishing a Telnet connection to the module. 
Ensure that the module has a valid IP address before saving 
changes to the COM port application. If the module does not 
have a valid IP address and the changes are saved, refer to 
Appendix C for instructions on clearing NVRAM in order to 
reestablish COM port communications.