Cabletron Systems DLE33-MA User Manual

Page of 202
SmartTrunk and the Configuration Screen
DLE22-MA,DLE32-MA,DLE23-MA and DLE33-MA User’s Guide
5-65
SMARTTRUNK CONFIGURATION menu item and pressing ENTER. 
The SmartTrunk Configuration screen displays.
Figure 5-25
SmartTrunk Configuration Screen
The following explains each field of the SmartTrunk Configuration 
screen:
Port #
Identifies the number of the port.
Interfaces with the Port Name “Backplane” may display on this 
screen. These ports may not be used for SmartTrunking. Poor 
network performance will result if backplane ports are used as 
SmartTrunk interfaces. Section 5.20.1 details all SmartTrunk 
configuration rules.
The DLE2X-MA and DLE3X-MA ports must be connected to a 
product that supports SmartTrunking for load sharing to 
function.
Firmware Revision:      XX.XX.XX
Smart Trunk Configuration
LKG-10855-98F
BOOTPROM Revision: XX.XX.XX
Module Type: DLE22-MA
Slot Number: X
MS 700 LOCAL MANAGEMENT
Event Message Line
Port #       Port Name       Connection      Smart Trunk State    
      Instance      # STPorts
1              Enet                  [USER]
 NONE
            0
           0
2              Enet                  [NETWORK]  SMARTTRUNKING
            1                   2
3              Enet                  [NETWORK]  SMARTTRUNKING
            1                   2
4              Enet                  [NETWORK]    SMARTTRUNKING                       2                   3
5              Enet                  [NETWORK]    SMARTTRUNKING                       2                   3
6              Enet                  [NETWORK]    SMARTTRUNKING                       2                   3
7              Enet                  [USER]             NONE                                            0                   0
8              Enet                  [USER]             NONE                                            0                   0
9              Enet                  [USER]             NONE                                            0                   0
10            Enet                  [USER]             NONE                                            0                   0
11            Enet                  [USER]             NONE                                            0                   0
12            Enet                  [USER]             NONE                                            0                   0
RETURN
ENABLE
NEXT
EXIT
---------
------------------ ---------------
-------------------------
-------------
-------------