Cabletron Systems DLE33-MA User Manual

Page of 202
Chapter 5: Local Management
5-82
DLE22-MA,DLE32-MA,DLE23-MA and DLE33-MA User’s Guide
5.24.3
Image File Download Using BootP
Set the DLE2X-MA and DLE3X-MA to download to FLASH using 
BootP as follows:
1.
Use the arrow keys to highlight the Download Method field.
2.
Use the SPACE bar to select BOOTP.
3.
Use the arrow keys to highlight the TFTP Gateway IP Addr field. Set 
the IP address of the TFTP gateway server (this defaults to the same IP 
address set in the TFTP Gateway IP Addr field in the General 
Configuration screen). 
4.
Use the arrow keys to highlight EXECUTE at the bottom of the screen 
and press ENTER. The message “BOOTP DOWNLOAD. WILL 
COMMIT TO FLASH. REBOOT IN PROGRESS...” displays in the 
event message line at the top of the screen and the new image is 
downloaded into FLASH memory.
5.25
PORT REDIRECT FUNCTION SCREEN
The Port Redirect Function screen, Figure 5-30, allows the user to set 
each one of the ports on the DLE2X-MA and DLE3X-MA as a source or 
destination port. A port can be set to have one or more destination ports. 
For example, port 1 can be set as a source port with three destinations, 
ports 2, 3, and 4. Traffic from port 1 is then automatically redirected to 
ports 2, 3, and 4. Port 1 can also serve as a destination port for other ports. 
The port redirect function is extremely useful for troubleshooting 
purposes, as it allows traffic to be sent to a particular port(s) where, with 
the use of an analyzer or RMON probe, all current traffic from the source 
port(s) can be examined.
The Port Redirect Function screen may not be available 
depending on the operational mode that has been set for the 
module. Refer to your Release Notes to see what operational 
modes support the Port Redirect Function. Refer to 
Section 5.15.9, Setting the Operational Mode, for instructions 
on configuring the operational mode of the module.