Chapter 5: Local Management
5-46
DLE22-MA,DLE32-MA,DLE23-MA and DLE33-MA User’s Guide
If the time entered is within the 1 to 30 minutes range, the Event Message 
Line at the top of the screen displays “SAVED OK”. If the entry is not 
valid, Local Management does not alter the current setting, but it does 
refresh the Screen Lockout Time field with the previous value.
5.15.9
Setting the Operational Mode
To set the Operational Mode, proceed as follows:
1.
Use arrow keys to highlight the Operational Mode field.
2.
Press the SPACE bar to step to the appropriate operation mode, 
(802.1D SWITCHING802.1Q SWITCHING).
3.
Use the arrow keys to highlight the SAVE command, then press 
ENTER. The warning screen shown in Figure 5-18 displays.
4.
Use the arrow keys to highlight the YES command and press ENTER. 
The changes are saved and the module reboots.
5.15.10 Setting the Management Mode
To set the management mode, perform the following steps:
1.
Use the arrow keys to highlight the Management Mode field:
Upon saving the new operational mode, the module will reboot.
If the DLE2X-MA and DLE3X-MA have been set to 802.1Q 
SWITCHING
, refer to your 
Port Based VLAN User’s Guide
 to 
configure the devices for this type of operation.
Upon saving the new Management Mode, the module will 
reboot.
If the module will be set to STANDALONE, ensure the following 
procedures have been completed:
The module has been assigned a unique IP address.
The module has been assigned SNMP community names from 
the module SNMP Community Names screen (Section 5.16). 
In STAND ALONE management mode, the module does not 
use the community names of the DLM6C-AA chassis.