Chapter 4: Troubleshooting
4-6
DLE22-MA, DLE32-MA, DLE23-MA and DLE33-MA User’s Guide
4.3
TROUBLESHOOTING CHECKLIST
If the DLE2X-MA or DLE3X-MA is not working properly, refer to 
Table 4-4 for a checklist of possible problems, causes, and recommended 
actions to resolve the problem.
Table 4-4
Troubleshooting Checklist 
Problem
Possible Cause
Recommended Action
All LEDs are OFF.
Loss of power to the 
DLM6C-AA chassis.
Check the proper connection 
of the power cable and its 
access to a live outlet.
DLE3X-MA or 
DLE2X-MA not properly 
installed.
Check the installation.
No Local 
Management 
Password screen.
Autobaud enabled. But 
baud rate has not yet 
been sensed.
Press ENTER (RETURN) 
(may take up to four times).
Terminal setup is not 
correct.
Refer to Chapter 5 for proper 
setup procedures.
Improper console cable 
pinouts.
Refer to Appendix A for 
proper console port pinouts.
Cannot contact the 
DLE32-MA or 
DLE22-MA from 
in-band 
management.
Improper Community 
Names Table.
Refer to Chapter 5 
for Community Names Table 
setup.
DLE2X-MA or 
DLE3X-MA does not 
have an IP address.
Refer to Chapter 5 for IP 
address assignment 
procedure.
Port is disabled.
Enable port.
No link to device.
Check link to device.
Port(s) goes into 
standby for no 
apparent reason.
DLE2X-MA or 
DLE3X-MA detects a 
looped condition.
Review network design and 
delete unnecessary loops.
User parameters (IP 
address, Device and 
Module name, etc.) 
are lost when the 
DLE2X-MA or 
DLE3X-MA is 
powered down or 
the front panel 
RESET button is 
pressed.
Mode switch (7), 
NVRAM Reset, was 
changed sometime 
before either cycling 
power or pressing the 
RESET button, causing 
the user-entered 
parameters to reset to 
factory default settings.
Reenter the lost parameters 
as necessary. Call your 
DIGITAL representative if 
problem continues.