Cabletron Systems 7C04-R User Manual

Page of 150
SMT/MAC Configuration
4-17
FDDI Management
TReq  (Requested Target Token  Rotation Time)
Displays the token rotation time bid made by the noted MAC during ring 
initialization, in milliseconds. T-Req is stored within the MIB in nanoseconds 
rather than milliseconds; SPMA converts nanoseconds to milliseconds according 
to the following formula:
(snmpFddiMACTReq) divided by 10
6
 = T-Req msec
You can use any SNMP Set Request tool to edit the T-Req value; just remember 
that you must enter your value in nanoseconds, not milliseconds.
TNeg
Displays the winning token rotation time submitted by an FDDI ring station 
during the ring initialization, in milliseconds. The station with the lowest token 
rotation time bid wins the right to initialize the ring.
Current Path
Indicates which FDDI ring the noted MAC is attached to:
Primary ––
 the MAC is physically on the primary path.
Secondary ––
 the MAC is physically on the secondary path.
Local ––
 the MAC is physically on an internal local path and is not associated 
with the dual ring.
Isolated ––
 the MAC is not associated with any physical path.
? ––
 SPMA cannot determine the current MAC path.
Charts, Graphs, and Meters
You can view both an FDDI MAC Chart and FDDI MAC Meters (and, if you are 
running SPMA in conjunction with HP Network Node Manager or IBM NetView, 
an FDDI MAC Graph) for each available MAC entity by clicking on the 
appropriate buttons at the bottom of the SMT/MAC Configuration window.
NOTES
Graphing capabilities are provided by an application that is included in HP Network Node 
Manager and IBM NetView; therefore, graphs are only available when SPMA is run in 
conjunction with one of these network management platforms. If you are running SPMA 
in a stand-alone mode or in conjunction with SunNet Manager, no graphing capabilities 
are available and no graph-related options will be displayed on buttons or menus. Note 
that the screens displayed in this guide will include the graph-related options where they 
are available; please disregard these references if they do not apply.
Only general information about charts, graphs, and meters is provided in the following 
sections; for more detailed information, see the SPMA Tools Guide.