Cabletron Systems pmn User Manual

Page of 150
Chapter 3: Installation
3-2
2M46-04R/2M46-04RDC User’s Guide
3.2
INSTALLING OPTIONS
If the 2M46-04R is to be installed with an optional Fast Ethernet Interface 
Module, refer to 
 for installation instructions. The installation 
instructions for the HSIMs are in the associated HSIM user’s guide.
3.3
INSTALLING THE 2M46-04R
The 2M46-04R may be installed on a tabletop, shelf, or in a 19-inch rack. 
describes the rackmount installation.
3.3.1
Tabletop or Shelf Installation
Tabletop and shelf installations must be within reach of the network 
cabling and meet the requirements listed below:
Locate the 2M46-04R within seven feet of an appropriately grounded 
power receptacle that meets the power supply requirements listed in 
. (This requirement does not apply to the 
2M46-04RDC.)
In a shelf installation, the shelf must support 13.6 kg (30 lb) of static 
weight for all devices.
Maintain a temperature of between 5°C (41°F) and 40°C (104°F) at 
the installation site with fluctuations of less than 10°C (18°F) per hour.
NOTE
Install any optional equipment before proceeding to 
To prevent possible damage to the unit, do NOT connect power 
to the 2M46-04R until instructed to do so.
!
CAUTION
Maintain a 2-inch clearance from the left, right, and rear sides 
of the device to provide adequate ventilation and prevent 
overheating.