Cabletron Systems SEH-24 User Manual

Page of 64
TROUBLESHOOTING
Page 5-2
2.
If the remote station is ready and the LNK LED is on, but no data 
passes through the port, one of two conditions may exist:
Network management has disabled the port. 
The port is segmented either because the collision detector was 
on for more than 110 
µ
sec. or the SEH detected more than 32 
consecutive collisions on the attached segment. The affected 
port remains segmented until a good packet is transmitted/
received without collisions.
If the LNK LED is still not on, contact Cabletron Systems Technical 
Support.
5.2
USING LANVIEW
The SEH incorporates the Cabletron Systems LANVIEW Status 
Monitoring and Diagnostics System. LANVIEW LEDs can help 
diagnose problems such as a power failure or a cable fault. The SEH 
includes the following LANVIEW LEDs:
PWR, for power status
MGMT, for management status
RCV (Receive), LNK (Link), and CLN (Collision) for Ethernet 
status.
Figure 5-1 provides a quick reference chart of LED locations and 
definitions. This chapter also includes a detailed description of each 
LED.