Cabletron Systems 9E138-36b User Manual

Page of 36
A-5
EPIM-C
EPIM-C
The EPIM-C supports thin-net coaxial cabling and is equipped with an internal 
Cabletron Systems TMS-3™ Transceiver. You can use the TERM switch on the 
front of the EPIM-C to set the internal 50-ohm terminator. This eliminates the 
need to connect the port to a tee-connector and terminator. Figure A-4 shows the 
setting for the terminator switch.
The link distance is up to 185 meters on the thin-net coaxial cables.
Figure A-4. EPIM-C
Connector Type
This connector type is a BNC receptacle, with gold center contact, for use with 
BNC type tee-connectors and RG-58 thin-net cable.
Grounding
For safety reasons, only one end of a thin-net segment should be connected to 
earth ground. Connection to earth ground at more than one point on the segment 
may cause dangerous ground currents. 
The BNC port of the Coaxial Interface Modules is not connected to earth ground.
EPIM-A and EPIM-X (AUI Port)
The EPIM-A is a DB-15 female connector used to attach segments to an external 
transceiver. The EPIM-X is equipped with dual internal transceivers. It has a DB15 
male connector used to attach segments to an AUI cable. Figure A-5 shows both 
modules.
EPIM-C
Internal Termination Switch
     = On (internally terminated)
     = Off (need external termination)
TERM