Cabletron Systems 9E138-12 User Manual

Page of 36
A-3
EPIM-F3
Transmitter power parameters are listed Table A-2.
EPIM-F3
The EPIM-F3 supports Single Mode Fiber Optic cabling. It has an internal 
Cabletron Systems FOT-F™ Fiber Optic Transceiver and is equipped with ST 
Connectors. Figure A-3 shows the EPIM-F3. Specifications for the EPIM-F3 ar
listed in Table A-3.
The link distance is up to 40 kilometers (max) and 25 kilometers (typical) on 
single mode fiber-optic cable as specified by ANSI SMF-PMD.
Table A-1. EPIM-F1 and EPIM-F2 Specifications
Parameter
Typical Value
Worst 
Case
Worst Case 
Budget 
Typical 
Budget
Receive Sensitivity
-30.5 dBm
-28.0 dBm
 —
Peak Input Power
-7.6 dBm
-8.2 dBm
 —
 —
Table A-2. Transmitter Power Parameters
Parameter
Typical Value
Worst 
Case
Worst Case 
Budget
Typical 
Budget
50/125 µm fiber
-13.0 dBm
-15.0 dBm
13.0 dB
17.5 dB
62.5/125 µm fiber
-10.0 dBm
-12.0 dBm
16.0 dB
20.5 dB
100/140 µm fiber
-7.0 dBm
-9.0 dBm
19.0 dB
23.5 dB
Error Rate
Better than 10 
-10
The transmitter power levels and receive sensitivity levels listed are Peak Power 
Levels after optical overshoot. A Peak Power Meter must be used to correctly 
compare the values given above to those measured on any particular port. If 
Power Levels are being measured with an Average Power Meter, then 3 dBm must 
be added to the measurement to correctly compare those measured values to the 
values listed (i.e., -30.5 dBm peak = -33.5 dBm average).
NOTE