Cabletron Systems SEH100TX-22 User Manual

Page of 52
Chapter 6: Troubleshooting
6-2
SEH100TX User’s Guide
2. If the remote station is ready and the LNK LED is on, but no data 
passes through the port, one of the following conditions may exist:
a.
Network management has disabled the port. Correct this condition 
by enabling the port through network management.
b. The port is segmented either because the collision detector was on 
for more than 110 
µ
s or the SEH detected more than 32 
consecutive collisions on the attached segment. The affected port 
remains segmented until a good packet is transmitted/received 
without collisions.
If the LNK LED is still off, contact Cabletron Systems Technical 
Support.
6.2
USING LANVIEW
The SEH incorporates the Cabletron Systems LANVIEW status 
monitoring and diagnostics system. LANVIEW LEDs help diagnose 
problems such as power failure or cable fault. The SEH includes the 
following LANVIEW LEDs:
PWR, for power status
MGMT, for management status
RCV (Receive), LNK (Link), and CLN (Collision) for Ethernet status
Figure 6-1 provides a quick reference chart of LED locations and 
definitions. This chapter also includes a detailed description of each LED.