Cabletron Systems CSX1000 User Manual

Page of 644
Workgroup Remote Access Switch     201
C
ONFIGURING
 A
LTERNATE
 A
CCESSES
X.25 Accesses
P
ERMANENT
 V
IRTUAL
 C
IRCUIT
 I
NFORMATION
Note:
SVCs and PVCs are specified in the X.25 Logical Channel Assignments section of the 
configuration. However, PVCs require additional configuration, which is done in this 
section.
1.
Follow the onscreen instructions to begin the configuration of a virtual circuit.
Note:
Default values are configured for each PVC when an access is newly created. You are given 
the opportunity to modify the PVC configuration (steps 2 through 7). If you are unsure of 
what to change, use the default configuration. Note that the packet sizes are limited to 128 
bytes for D-channel configurations.
2.
Enter the Logical Channel Number (LCN) that is to be used for this PVC. LCN values are 
obtained from the PPSN carrier.
3.
Enter the nonstandard default transmit window size.
4.
Enter the nonstandard default receive window size.
5.
Select the nonstandard default transmit packet size.
6.
Select the nonstandard default receive packet size.
7.
Select the nonstandard default transmit throughput class.
8.
Select the nonstandard default receive throughput class.
9.
After all of the above information has been entered for your PVC, repeat the above steps to add 
the rest of your PVCs (up to the maximum number of PVCs)
X.25 C
ONFIGURATION
 E
LEMENTS
X.25 L
INE
 C
ONFIGURATION
 E
LEMENTS
L
INE
 I
D
 N
UMBER
From the displayed list of available lines, this is the Id Number of the previously defined line that 
is to be used for this X.25 connection. A line that is in use by another type of access will not be 
available for use by an X.25 access.
X.25 A
CCESS
 N
AME
The user defined name that will be used to identify this X.25 access. This name can consist of 1 to 
16 non-blank, alpha-numeric characters. The X.25 access name is provided as an aid in helping to 
track events occurring on an X.25 access.
L
OCAL
 DTE A
DDRESS
The X.121 address to be used as the local DTE address. The X.121 address is the public data network 
address assigned by your X.25 provider. The local DTE (Data Terminal Equipment) in our 
application refers to the CyberSWITCH.