Cabletron Systems CSX1000 User Manual

Page of 644
Workgroup Remote Access Switch      387
P
ROBLEM
 D
IAGNOSIS
Dedicated Connections
6.
If the above actions fail to correct the problem, then call your phone company (carrier) to check 
the status of the line. If it is determined that there is no problem with the line, contact Customer 
Support.
Problem:
A WAN line is unavailable, and the following two messages are displayed together (to display 
messages, issue the 
dr
 console command):
WAN card in slot <slot #> signals it is operational
Abnormal response rcvd: state=-1 msg=73 reason=6 cc state=-1
Action:
1.
Check the configuration. Verify that all lines are configured with corresponding data links. If 
this is not the case, add data links to all configured lines.
D
EDICATED
 C
ONNECTIONS
Problem:
A dedicated connection is not functioning.
Action:
If the dedicated connection is not up, this usually indicates that the device could not be validated 
for some reason. Check the configuration for the device that will be using the dedicated connection, 
and make any necessary corrections.
F
RAME
 R
ELAY
 C
ONNECTIONS
Problem:
The system displays the following message in the report log.
Unexpected error during transmission of LMI frame
Action:
Start up the run-time configuration utility CFGEDIT by entering the following console command:
cfgedit
For the Frame Relay access, change the Frame Relay LMI type.
Save the configuration change, and restart the system.
Problem:
The system displays one of the following message in the report log.
[FR_IETF] Authentication Failure of remote device “NAME”
[FR_IETF] Off-node Authentication Failure of remote device “NAME”
Action:
The device indicated device database does not have a device entry corresponding to the permanent 
virtual circuit. Start up the run-time configuration utility CFGEDIT by entering the following 
console command:
cfgedit
For the Frame Relay PVC, change the PVC name to match the remote device name.