Cabletron Systems CSX1000 User Manual

Page of 644
USER’S GUIDE
410      CyberSWITCH
D
IAL
 O
UT
Problem:
A Dial Out call was not completed successfully.
Action:
1.
If you issued the 
call device <device name>
 console command to initiate the call, check 
to see that you entered the device name correctly. Device names are case sensitive.
2.
If you issued the 
call peer <telephone number data rate> 
console command to 
initiate the call, check to see that you entered the correct telephone number and data rate. The 
telephone number must contain all required prefixes such as the area code, or a “9 if Centrex 
is used. 
3.
If you have entered the call device or the call peer command correctly, follow the set up and 
actions listed below.
Set Up:
1.
Enable the call trace messages by issuing the 
trace on 
console command. 
2.
Erase the current system messages (issue the 
er
 console command). 
3.
Initiate a call to a remote device by issuing the 
call device <device name> 
console 
command. 
4.
Display the system messages (issue the 
dr
 console command). 
5.
Look for the following call request messages among the system messages. 
Out - CALL RQST ACK Call Id=<call Id> Rate=<data rate> Slot=<slot#> 
Port=<port#> Chans=<bearer channel map> TN=<telephone number di-
aled> Ces=<communication endpoint suffix> ConnId=<connect Id
In - CALL RQST ACK CallId=<call Id> Slot=<slot#> Port=<port#> 
CES=<ces> ConnId=<connection Id>
In - PROCEEDING Call Id=<call Id> Slot=<slot #> Port=<port #> 
Chans=<bearer channel map> Ces=<communication endpoint suffix> 
ConnId=< connect Id>
In - CONNECT Call Id=<call Id> Slot=<slot#> Port=<port #> 
Chans=<bearer channel map> Ces=<communication endpoint suffix> 
ConnId=<connect Id>
Action:
1.
If the system does not report a call request message for the remote device, then the system did 
not attempt to make a call. Check to see if there is enough call resources (lines, channels, 
supported connections) to make the missing call. For example, if your system supports only 
one BRI line, and you have no hunt groups, then only two active connections are possible. The 
system would not attempt to make a third call. 
If this is not the case, contact Customer Support.
2.
If the system reports a call request message but it does not connect, then the system attempted 
to make a call. Check to see if the remote device has already completed the installation and 
verification processes, and is currently running with no active errors.