LED I
NDICATORS
Service Indicator
The table below provides an error description corresponding to the number of consecutive LED 
blinks: 
* FSB: First Stage Boot;   SSB: Second Stage Boot. 
S
ERVICE
 I
NDICATOR
 B
LINKS
If the Service indicator blinks at any time during system operation, access your administrative 
console (using the status command) for further information. One or more of the following messages 
should be displayed: 
OUT  SVC  1
OUT  SVC  2
OUT  SVC  3
OUT  SVC  4
OUT  SVC  5
LAN XMIT ERROR
These messages indicate a problem with the LAN or BRI connections, or an incorrectly 
programmed SPID. 
The Service indicator will also blink if semipermanent devices are configured, and a connection to 
one of these devices is faulty. Use the sp command to check the status of the semipermanent 
connection. Once you correct the problem, the Service indicator will automatically turn off.
If you have made corrections and the Service indicator continues to blink, contact Cabletron 
Systems Technical Support.
Number of Blinks
Error Description
1
Failure during erasure of main block during SSB* recovery
2
Failure during programming of main block during SSB 
recovery
3
Timed out during recovery of SSB
4
Individual record error during recovery of SSB
5
Communications error during recovery of SSB
6
Incompatibility between FSB* and new SSB versions
7
Currently not used
8
Bad address information contained in SSB received during 
recovery
9
SSB, received during Recovery, contained a bad checksum 