Cabletron Systems CSX1000 User Manual

Page of 644
USER’S GUIDE
78      CyberSWITCH
To perform a remote upgrade, first upgrade to the latest SSB, if required, then upgrade the OSW. 
The Release Notes will indicate whether or not the SSB needs to be upgraded.
Note:
If, during a remote upgrade, the compressed file set cannot be uncompressed into the Flash 
File System due to a lack of space, the compressed file set will not be deleted from the Flash 
File System and the previous version of the OSW will be booted. If the OSW determines 
there is a compressed file set (a file suffix of .OSW) in the Flash File System, then the 
following message is logged in the system log:
OSW, <OSWFileName>, found in the Flash File System. The OSW has not been 
updated from this file due to insufficient Flash File System space. 
Please delete unnecessary files from the system.
It is possible that you will not have enough room in the \
SYSTEM
 directory to TFTP the 
upgrade file to the system. In this case:
Delete all files in the directory except
 nex.bin
 and 
iop.bin
.
Issue  a 
flash reclaim
 command to gain the lost space (this will destroy the backup 
copy of your configuration, you will be unable to issue restore command unless you 
have saved at least one set of changes).
If the upgrade still fails, delete the 
nex.bin
 and 
iop.bin
 and again reclaim the space. 
Your upgrade should now work. IMPORTANT: Do not restart the CyberSWITCH until 
the upgrade is complete.
If you are upgrading from a previous version of system software, the above message will 
not be displayed. In this case, the system continually restarts, attempting to install the OSW 
package each time.
R
EMOTE
 U
PGRADE
 
OF
 
THE
 S
ECOND
 S
TAGE
 B
OOT
 (SSB)
WARNING:
If power is lost on the remote CyberSWITCH during this process, a local upgrade of the 
SSB may be necessary before the system can again function.
To remotely upgrade the SSB, follow these steps:
1.
Telnet to the CyberSWITCH and login as admin. 
2.
Enable
, the TFTP client, and the TFTP server with admin access rights.
3.
Using the TFTP client on the remote workstation, TFTP the 
recover1
 file to the 
CyberSWITCH in binary mode. Be sure to use the file’s full pathname (for example: 
D:\CSX1204\US\IPIPX\RECOVER1)
. The exact method to transfer varies, depending upon 
your TFTP client.
4.
At the system prompt, recover the SSB by issuing the following command:
flash recover
The system will ask you if you are sure you want to remotely recover the SSB, and warn you 
of the potential risk in case of a power failure while the SSB is being recovered. Answer “yes” 
to the prompt. The window of vulnerability ends after 5 or 10 seconds, when the system tells 
you that the SSB was successfully recovered.