Cabletron Systems 9E428-36 User Manual

Page of 18
9E428-12/36 and 9E429-12/36 Module Specific Information
12
MULTICASTS 
Displays the number of multicasts received. 
LINK STATUS 
Indicates whether there is a physical connection from this port to another 10Base-
FL device. One of the following values appears:
Link - There is a 10Base-FL link signal present; there is a valid physical 
connection from this port to another 10Base-FL device.
No Link - There is no 10Base-FL link signal present; there is no valid physical 
connection from this port to another 10Base-FL device.
N/A
PORT TYPE 
Displays one of the following values:
MMF ST
SMF ST
PORT STATUS 
Indicates whether the port has been turned on or off administratively. You will see 
one of the following values:
ENABLED - The port is turned on administratively.
DISABLED - The port is turned off administratively.
APPLICATION 
Displays BRIDGING, indicating that the port is operating as a bridge with a high-
speed backbone connection.
OPERATION MODE
Displays one of the following values:
STANDARD ENET - The port can either transmit data or receive data, but not 
both at the same time. Therefore, the port is running at 10 Mbps.
FULL DUPLEX - The port can transmit and receive data at the same time. 
Therefore, the port is running at 20 Mbps.
Enable or disable ports from the Bridge Configuration screen.