Cisco Systems Intelligent Gigabit Ethernet Switch Modules for the IBM BladeCenter, Software Configuration Guide
24R9746
Chapter 5      Configuring Switch-Based Authentication
Controlling Switch Access with RADIUS
Beginning in privileged EXEC mode, follow these steps to configure per-server RADIUS server 
communication. This procedure is required.
To remove the specified RADIUS server, use the no radius-server host hostname | ip-address global 
configuration command. 
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
radius-server host {hostname | 
ip-address} [auth-port port-number
[acct-port port-number] [timeout 
seconds] [retransmit retries] [key 
string]
Specify the IP address or host name of the remote RADIUS server host.
(Optional) For auth-port port-number, specify the UDP destination 
port for authentication requests.
(Optional) For acct-port port-number, specify the UDP destination 
port for accounting requests.
(Optional) For timeout seconds, specify the time interval that the 
switch waits for the RADIUS server to reply before resending. The 
range is 1 to 1000. This setting overrides the radius-server timeout 
global configuration command setting. If no timeout is set with the 
radius-server host command, the setting of the radius-server 
timeout
 command is used.
(Optional) For retransmit retries, specify the number of times a 
RADIUS request is resent to a server if that server is not responding 
or responding slowly. The range is 1 to 1000. If no retransmit value is 
set with the radius-server host command, the setting of the 
radius-server retransmit global configuration command is used.
(Optional) For key string, specify the authentication and encryption 
key used between the switch and the RADIUS daemon running on the 
RADIUS server. 
Note
The key is a text string that must match the encryption key used 
on the RADIUS server. Always configure the key as the last item 
in the radius-server host command. Leading spaces are ignored, 
but spaces within and at the end of the key are used. If you use 
spaces in your key, do not enclose the key in quotation marks 
unless the quotation marks are part of the key.
To configure the switch to recognize more than one host entry associated 
with a single IP address, enter this command as many times as necessary, 
making sure that each UDP port number is different. The switch software 
searches for hosts in the order in which you specify them. Set the timeout, 
retransmit, and encryption key values to use with the specific RADIUS 
host.
Step 3
end
Return to privileged EXEC mode.
Step 4
show running-config
Verify your entries.
Step 5
copy running-config startup-config
(Optional) Save your entries in the configuration file.