IBM 12.1(22)EA6 User Manual

Page of 550
 
20-3
Cisco Systems Intelligent Gigabit Ethernet Switch Modules for the IBM BladeCenter, Software Configuration Guide
24R9746
Chapter 20      Configuring System Message Logging
Configuring System Message Logging
This example shows a partial switch system message:
00:00:46: %LINK-3-UPDOWN: Interface Port-channel1, changed state to up
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet0/17, changed state to up
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet0/20, changed state to up
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/17, changed 
state to down 2
*Mar  1 18:46:11: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
18:47:02: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
*Mar  1 18:48:50.483 UTC: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36) 
Default System Message Logging Configuration
 shows the default system message logging configuration.
MNEMONIC
Text string that uniquely describes the message.
description
Text string containing detailed information about the event being reported.
Table 20-1
System Log Message Elements (continued)
Element
Description
Table 20-2
Default System Message Logging Configuration
Feature
Default Setting
System message logging to the console
Enabled.
Console severity
Debugging (and numerically lower levels; see 
Logging buffer size
4096 bytes.
Logging history size
1 message.
Timestamps
Disabled.
Synchronous logging
Disabled.
Logging server
Disabled.
Syslog server IP address
None configured.
Server facility
Local7 (see 
Server severity
Informational (and numerically lower levels; see