5-4   SmartSwitch ATM User Guide
PVC Connections
  Virtual Ports and Static Connections
5.
Connect the workstations to their respective ports.
6.
Configure the workstations for the same subnet and VPCI/VCI pair = 0/101.
The broadcasting workstation on port 
7a1
 can send traffic to the receiving workstations on ports 
7a2
7a3
, and 
7a4
.
5.1.3
Connecting to Local Switch Client Through a PVC
All PVC connections to an ATM SmartSwitch local client use the CPU port. On a SmartSwitch 6500, this port is either 
7B4
 or 
8B4
 depending on the slot in which the master TSM/CPU module resides. Because of the SmartSwitch 6500’s 
redundancy capability, the CPU port should always be designated as 
CPU
. Using 
CPU
 assures that the PVC connects to 
the active CPU in the event of fail-over. On all other SmartSwitch ATM switches (2500, 6A000, or 9A100), the CPU 
port is 
B4
, however, as with the SmartSwitch 6500, the value 
CPU
 can also be used.
Follow these instructions to connect an end node to an ATM SmartSwitch’s local client through a point-to-point PVC.
1.
Use 
add pvc
 to create the PVC.
SmartSwitch # add pvc
ConnType(PTP)                             :
Port-1-Number()                           : 7a1
Port-1-VPCI()                             : 0
Port-1-VCI()                              : 100
Port-2-Number()                           : cpu   
— The CPU port
Port-2-VPCI()                             : 0
Port-2-VCI()                              : 101
Port1-to-Port2TrafficDescriptorIndex()    : 2
Port2-to-Port1TrafficDescriptorIndex()    : 2
SmartSwitch #
2.
Use 
add ipatmclient
 to create an IP over ATM local client.
SmartSwitch # add ipatmclient
ClientNumber(0)                           : 2      
— Set client number 2
ServerType(None)                          : local  
— ARP server is on the switch
ServerAddress()                           :
IPAddress()                               : 100.1.1.0
NetMask(255.0.0.0)                        :
MTU(9180)                                 :
SmartSwitch #
3.
Use 
add ipatmpvc
 to associate the end node’s IP address with the PVC.
SmartSwitch # add ipatmpvc
ClientNumber(0)                           : 2       
— Specify local client number
DestinationVPCI(0)                        :
DestinationVCI(33)                        : 101     
—VCI to CPU port was specified as 101
SmartSwitch #
4.
Connect the end node to port 
7a1
 of the ATM SmartSwitch.