Cabletron Systems SFCS-200BX User Manual

Page of 180
4-5
Switch Setup
4.4.2
Installing the Rack-mount Brackets
To install the rack-mount brackets and cable relief strain rail, use the follow-
ing procedure:
1.
Carefully place the SFCS-200BX unit upside down on a clean, flat,
sturdy work surface with the front of the unit still facing front.
2.
Using a Phillips screwdriver, remove the four feet from the bottom
of the unit.
3.
Each rack-mount bracket has three screws that secure the bracket
to the bottom of the unit. The screw closest to the front of the unit
is used to secure the bracket to the bottom of the unit as well as
secure the cable relief strain rail to the front of the unit. Tighten the
three screws to secure the left bracket, marked HWST0027-0001,
and the left side of the cable relief strain rail to the left side of the
unit. Tighten the three screws to secure the right bracket, marked
HWST0027-0002, and the right side of the cable relief strain rail to
the right side of the unit.
CAUTION
When attaching the rack-mount brackets, the
use of screws other than those provided could
result in damage to the unit.
4.
Once the brackets and the cable relief strain rail are secure, choose
a rack position for the SFCS-200BX. The SFCS-200BX should be
placed right side up in the rack with the front of the unit facing
forward.
CAUTION
When it is mounted in the equipment rack, do
not use the SFCS-200BX chassis to support
other equipment. This could overload the
mounting brackets and cause damage to the
unit.