Cabletron Systems 2E43-51 User Manual

Page of 168
Using LANVIEW
2E43-51/2E43-51R User’s Guide
4-3
RX
(Receive)
of ENET 
1 – 4 and 
Ports 5 
and 6
Off
No link. No activity. 
Port enabled or 
disabled.
No error.
Green
Blinking. Port 
disabled.
No error.
Amber
Flashing. Port 
enabled, activity.
No error.
Red
Diagnostic failure.
Contact the Cabletron 
Systems Global Call Center 
for assistance.
TX
(Transmit)
LED of 
ENET 
1 – 4 and 
Ports 5 
and 6
Off
Port enabled, and no 
activity.
Should flash green 
every two seconds 
indicating BPDUs 
being sent if STA is 
enabled and there is a 
valid link.
1. Ensure that the STA is 
enabled and that there is a 
valid link.
2.  Contact the Cabletron 
Systems Global Call Center 
for assistance.
Green
Flashing. Indicates 
activity. Rate indicates 
data rate.
No action.
Amber
Blinking. Port in 
standby. 
Port may be disabled 
due to Spanning Tree.
1.  Ensure that the port is not 
disabled. 
2. Contact the Cabletron 
Systems Global Call Center 
for assistance.
Red
Flashing. Indicates 
collision rate. 
No action.
Solid. Diagnostic 
failure. 
Contact the Cabletron 
Systems Global Call Center 
for assistance.
LINK
Ports of 
ENET 
1 – 4
Amber
Solid. A link is 
established with the 
device connected to 
the port.
No action.
Flashing. Link 
established, but 
administratively 
disabled.
No action.
Off. No link. 
No action.
Table 4-1
LANVIEW LEDs (Continued)
LED
Color
State
Recommended Action